Đăng ký Đăng nhập
Trang chủ Kỹ thuật - Công nghệ Hóa học - Dầu khi D 1512 – 95 r00 ;carbon black—ph value...

Tài liệu D 1512 – 95 r00 ;carbon black—ph value

.PDF
4
310
94

Mô tả:

Designation: D 1512 – 95 (Reapproved 2000) Standard Test Methods for Carbon Black—pH Value1 This standard is issued under the fixed designation D 1512; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense. TEST METHOD A—BOILING SLURRY 1. Scope 1.1 These test methods, Test Method A—Boiling Slurry and Test Method B—Sonic Slurry, are used to indicate the pH of the carbon black surface by measuring the pH of water in contact with the carbon black. 4. Apparatus 4.1 pH Meter, (digital is recommended) having an accuracy of 60.05 pH and equipped with a combination electrode and RNC connector. 4.2 Container, stainless steel or copper, 125 cm3 or larger. 4.3 Hot Plate. 4.4 High Speed Mill, Mixer or Mortar and Pestle. 4.5 Beakers, glass, 100 cm3 graduated with watch glasses. NOTE 1—The pH of the carbon black is often used in this industry to indicate the relative acidity or alkalinity of carbon black and will be used in the remainder of these test methods to describe this property. NOTE 2—Test Method A and Test Method B do not always give the same results. 1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 5. Reagents 5.1 Purity of Reagents—Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available.5 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determination. 5.2 Purity of Water— Unless otherwise indicated, references to water shall be understood to mean reagent water as defined by Type 1 in Specification D 1193. 5.3 Distilled Water, high purity. 5.4 Buffer Solutions, pH of 4.00, 7.00, and 10.00. 5.5 Acetone, reagent grade. 2. Referenced Documents 2.1 ASTM Standards: D 1193 Specification for Reagent Water2 D 1799 Practice for Carbon Black—Sampling Packaged Shipments3 D 1900 Practice for Carbon Black—Sampling Bulk Shipments3 D 4483 Practice for Determining Precision for Test Method Standards in the Rubber and Carbon Black Industries3 E 70 Test Method for pH of Aqueous Solutions with the Glass Electrode4 6. Sampling 6.1 Samples shall be taken in accordance with Practices D 1799 or D 1900. 3. Significance and Use 3.1 The pH level of a carbon black is known to affect the vulcanization of some rubber compounds. 7. Procedure 7.1 Pulverize pelleted or lumpy carbon black to a fine powder, using either the high speed mixer or mortar and pestle. 7.2 Weigh 5 g of carbon black into a 100 cm3 glass beaker. 1 These test methods are under the jurisdiction of ASTM Committee D24 on Carbon Black and are the direct responsibility of Subcommittee D24.31 on Non-Carbon Black Components of Carbon Black. Current edition approved Sept. 10, 1995. Published November 1995. Originally published as D 1512 – 75. Last previous edition D 1512 – 94. 2 Annual Book of ASTM Standards, Vol 11.01. 3 Annual Book of ASTM Standards, Vol 09.01. 4 Annual Book of ASTM Standards, Vol 15.05. 5 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed by the American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville, MD. Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. 1 D 1512 – 95 (2000) 7.3 Add 50 cm3 of boiling, distilled water prepared in a stainless steel beaker and 2 to 3 drops of acetone to facilitate wetting of the sample. results (or determinations) produced in separate laboratories that differ by more than 1.53 pH units must be considered as suspect and dictates that appropriate investigative or technical/ commercial actions be taken. 9.2 Bias—In test method terminology, bias is the difference between average test value and the reference (true) test property value. Reference values do not exist for this test method since the value or level of the test property is exclusively defined by the test method. Bias, therefore, cannot be determined. NOTE 3—A stainless steel beaker is used to eliminate contamination during boiling. 7.4 Cover the glass beaker with a watch glass and boil the mixture for 15 min, but do not allow all the liquid to evaporate. 7.5 Let the mixture cool to room temperature in an atmosphere free from chemical fumes which might contaminate the sample. 7.6 Standardize the pH meter with the buffer solutions. Rinse the electrode with distilled water and wipe clean after each test. 7.7 Place the electrode in the sludge, rotate gently in alternate directions until a constant pH is obtained, and record the pH to the nearest 0.05 unit. TEST METHOD B—SONIC SLURRY 10. Apparatus 10.1 pH Meter, (digital is recommended) having an accuracy of 6 0.05 pH and equipped with a combination electrode and RNC connector. 10.2 Container, stainless steel or copper, 125 cm3 or larger. 10.3 Ultrasonic Stirring Bath6 , two-position. 10.4 Magnetic Spinbars, 4.8 mm (3⁄16 in.) or 6.4 mm (1⁄4 in.) by 22.4 mm (7⁄8 in.) long, coated with a fluorocarbon polymer, such as TFE-fluorocarbon. 10.5 Beakers, glass, 30 cm3 graduated with watch glasses. NOTE 4—Refer to Test Method E 70 for a definition of pH and a highly detailed procedure for making pH measurements. 7.8 Rinse the electrode with distilled water and wipe clean. Keep the electrode soaking in distilled water when not in use. 8. Report 8.1 Report the following information: 8.1.1 Proper identification of the sample, 8.1.2 Result obtained, reported to the nearest 0.05 unit, and 8.1.3 Test Method used, A or B. 11. Reagents 11.1 Purity of Reagents—Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available.5 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determination. 11.2 Purity of Water— Unless otherwise indicated, references to water shall be understood to mean reagent water as defined by Type 1 in Specification D 1193. 11.3 Distilled Water, high-purity. 11.4 Buffer Solutions, pH of 4.00, 7.00, and 10.00. 11.5 Acetone, reagent grade. 9. Precision and Bias 9.1 Test Method A: 9.1.1 This precision and bias has been prepared in accordance with Practice D 4483. Refer to this practice for terminology and other statistical details. 9.1.2 The precision results in this precision and bias give an estimate of the precision as described in the following paragraphs. The precision parameters should not be used for acceptance/rejection testing of any group of materials without documentation that they are applicable to those particular materials and the specific testing protocols that include this test method. 9.1.3 A Type 1 interlaboratory precision program was conducted in 1990. Both repeatability and reproducibility represent short term testing conditions. Eight laboratories tested four carbon blacks (Samples A through D), twice on two different days. A test result is the value obtained from a single determination. Acceptable difference values were not measured. 9.1.4 The results of the precision calculations are given in Table 1 with the materials arranged in ascending mean level order of the pH value. 9.1.5 The precision for the pooled values for pH value may be expressed as follows: 9.1.5.1 Repeatability— The repeatability, r, of the pH value has been established as 0.5 pH units. Two single test results (or determinations) that differ by more than 0.5 pH units must be considered suspect and dictates that some appropriate investigative action be taken. 9.1.5.2 Reproducibility— The reproducibility, R, of the pH value has been established as 1.53 pH units. Two single test 12. Sampling 12.1 Samples shall be taken in accordance with Practices D 1799 or D 1900. 13. Procedure 13.1 Weigh 1.5 g of carbon black into a 30 cm3 beaker. 13.2 Insert a magnetic spinbar into the beaker and add 20 3 cm of distilled water and 2 to 3 drops of acetone to aid dispersion. NOTE 5—The water should be boiled in a stainless steel beaker and cooled prior to use to remove dissolved carbon dioxide. 13.3 Cover the beaker with a watch glass and insert it into the ultrasonic bath which contains water to a depth of 40 mm that is 5 to 10°C below ambient temperature. 6 A unit which has been found suitable for this test is available upon custom order from Micro-Star 2000, Inc., 255 Bradwick Dr., Unit 21, Concord, Ontario, Canada L4K 1K7. 2 D 1512 – 95 (2000) TABLE 1 ASTM Test Method Precision—Type 1 pH (Method “A”)A NOTE 1—Symbols are defined as follows: Sr r (r) SR R (R) = = = = = = Within laboratory standard deviation. Repeatability (in measurement units). Repeatability (in percent). Between laboratory standard deviation. Reproducibility (in measurement units). Reproducibility (in percent). Writtin Laboratories Material Mean Level of pH Sample A Sample B Sample C Sample D Pooled or averaged values 3.72 6.71 6.92 8.35 6.42 Between Laboratories Sr r (r) SR R (R) 0.224 0.133 0.173 0.160 0.18 0.633 0.377 0.490 0.453 0.50 17.037 5.618 7.077 5.425 7.74 0.552 0.508 0.543 0.555 0.54 1.562 1.438 1.536 1.571 1.53 42.041 21.427 22.188 18.829 23.78 A This is short-term precision (days). 15.1.1 This precision and bias has been prepared in accordance with Practice D 4483. Refer to this practice for terminology and other statistical details. 15.1.2 The precision results in this precision and bias give an estimate of the precision as described in the following paragraphs. The precision parameters should not be used for acceptance/rejection testing of any group of materials without documentation that they are applicable to those particular materials and the specific testing protocols that include this test method. 15.1.3 A Type 1 interlaboratory precision program was conducted in 1990. Both repeatability and reproducibility represent short term testing conditions. Eight laboratories tested four carbon blacks (Samples A through D), twice on two different days. A test result is the value obtained from a single determination. Acceptable difference values were not measured. 15.1.4 The results of the precision calculations are given in Table 2 with the materials arranged in ascending mean level order of the pH value. 15.1.5 The precision for the pooled values for pH value may be expressed as follows: NOTE 6—Use small pieces of ice to control bath temperature. 13.4 Adjust the magnetic stirrer to give vigorous stirring by the spinbar, and turn on the sonic power for 3 min to equilibrate the mixture. NOTE 7—If a combination ultrasonic stirring bath is not available, use alternate periods of 1 min of ultrasonic agitation and 1 min of magnetic spin stirring for a total time of 6 min. 13.5 Remove the beaker from the ultrasonic bath, place the electrode in the aqueous dispersion (slurry), allow a 2-min equilibration period, then stir the slurry with the electrode and record the pH to the nearest 0.05 unit (see Note 4). 13.6 Rinse the electrode with distilled water and wipe clean. Keep the electrode soaking in distilled water when not in use. 14. Report 14.1 See Section 8. 15. Precision and Bias 15.1 Test Method B: 7 7 Supporting data are available from ASTM headquarters. Request RR: D24–1023. TABLE 2 ASTM Test Method Precision—Type 1 pH (Method “B”)A NOTE 1—Symbols are defined as follows: Sr r (r) SR R (R) = = = = = = Within laboratory standard deviation. Repeatability (in measurement units). Repeatability (in percent). Between laboratory standard deviation. Reproducibility (in measurement units). Reproducibility (in percent). Writtin Laboratories Material Sample A Sample B Sample C Sample D Pooled or averaged values Mean Level of pH 4.11 7.51 7.83 9.12 7.15 Between Laboratories Sr r (r) SR R (R) 0.183 0.147 0.134 0.182 0.16 0.519 0.417 0.378 0.516 0.46 12.619 5.543 4.830 5.656 6.46 0.596 0.419 0.408 0.357 0.45 1.686 1.185 1.155 1.011 1.29 40.992 15.766 14.750 11.085 17.99 A This is short-term precision (days). 3 D 1512 – 95 (2000) 15.1.5.1 Repeatability— The repeatability, r, of the pH value has been established as 0.46 pH units. Two single test results (or determinations) that differ by more than 0.46 pH units must be considered suspect and dictates that some appropriate investigative action be taken. 15.1.5.2 Reproducibility— The reproducibility, R, of the pH value has been established as 1.29 pH units. Two single test results (or determinations) produced in separate laboratories that differ by more than 1.29 pH units must be considered as suspect and dictates that appropriate investigative or technical/ commercial actions be taken. 15.2 Bias—In test method terminology, bias is the difference between an average test value and the reference (true) test property value. Reference values do not exist for this test method since the value or level of the test property is exclusively defined by the test method. Bias, therefore, cannot be determined. 16. Keywords 16.1 carbon black; pH ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or [email protected] (e-mail); or through the ASTM website (www.astm.org). 4
- Xem thêm -

Tài liệu liên quan