Mô tả:
REBOILER APPLICABILITY
Type
Flow
Layout
Vaporizatio
n Range %
Kettle
Gravity
Horizontal
20-100 P
20-80 R
Thermoshyphon
Gravity
Once-through,
vertical
20-30 R
Thermoshyphon
Gravity
Circulating,
vertical
20-30 PP
20-100 O
Thermoshyphon
Gravity
Horizontal
Forced circulation
Forced
Horizontal -C
20-40 PP,R
20-60 PP,P
20-100 O
20-60
Sub-in bundle
None
Horizontal
0-100
Falling film
Gravity
Vertical, cocurrent
0-90
Falling film
Pumped Vertical, cocurrent
0-90
Falling film
Gravity
0-80
Falling film
Pumped Horizontal,
spray
distribution
Horizontal (alltype)
Vertical (all-type)
Vertical,
counter-current
0-60
Suited for
High vaporization -4
Vacuum service -3
Two phase feed -4
Simple hydraulics
Wide boiling range mixtures -4
Reduced piping -3
Lower duties
High purity system
Reduced piping -3
High vaporization -4
Lower duties
High purity systems
Large sizes -3
Reduced pressure drop
Problems with
Dirt collection
Heavy end accumulation
Large size and higher cost
Heat flux limits
Vacuum services -2
Tower height requirements
Vacuum services -2
Tower height requirements
Complex return flow, flow instability in piping
Difficult to size
High viscosity -3
Extra pump cost, size, power and
Fouling service -4
maintenance
Higher once-through vaporization
Eliminate process piping -4
Dirty service -1
Vessel foundation loads
Bundles maintenance
Require attention to tower baffling and level
control
Bundle length limited by tower diameter
Heat sensitive system -4
Overall unit height
Vacuum systems -3
Sticky fouling systems
Complex liquid distribution at high
vaporizations
High viscosity
Heat sensitive system -4
Sticky fouling systems
Vacuum systems -3
Complex liquid distribution at high
vaporizations
High viscosity
Heat sensitive system -4
Sticky fouling systems
Vacuum systems -3
Complex liquid distribution at high
Adds extra fractionation
vaporizations
High viscosity
Heat sensitive system -4
Vacuum systems -3
Large sizes, Dirty services
Reduced plot area required -3
Dirty and fouling services -2
Large sizes
P= Possible, R= Recommended, PP= Per pass, O= Overall, C= Most common, 4= Excellent, 3= Good, 2 = Poor, 1= Avoid
Notes: Vaporization range in percent of nets liquid traffic entering the reboiler
- Xem thêm -